OPERATOR & MAINTENANCE MANUAL
PAGE
‐
55
6.4
Engine
Coolant
Changing
Coolant:
Open
the
radiator
drain
ball
valve,
located
on
the
top
of
the
generator
base
tank,
and
drain
coolant.
After
draining,
close
the
drain
ball
valve.
Remove
the
coolant
inlet
cap.
Remove
the
radiator
cap.
Pour
new
coolant
into
the
radiator
up
to
the
radiator
inlet
top.
Close
the
radiator
cap
and
coolant
inlet
cap.
WARNING
:
Avoid
injury!
The
radiator
will
be
hot
and
can
burn
skin.
Built
‐
up
pressure
may
cause
explosive
release
of
coolant
when
the
radiator
cap
is
removed.
Shut
off
engine
and
allow
it
to
cool.
Do
not
remove
cap
unless
the
radiator
and
the
engine
are
cool
to
touch
with
bare
hands.
Slowly
loosen
the
cap
to
the
first
stop
to
release
all
pressure,
then
remove
cap.
Содержание S10KS
Страница 1: ...PROMAC LEADING THE WAY OPERATOR MAINTENANCE MANUAL...
Страница 2: ...S10KS GENERATING SET OPERATOR MAINTENANCE MANUAL Edition A A Date 5 May 2011...
Страница 16: ...OPERATOR MAINTENANCE MANUAL PAGE 12 3 3 Generator Layout and Major Components...
Страница 18: ...OPERATOR MAINTENANCE MANUAL PAGE 14 3 4 Control Cabinet and Panel 3 4 1 Control Cabinet...
Страница 20: ...OPERATOR MAINTENANCE MANUAL PAGE 16 3 4 2 Control Panel...
Страница 28: ...OPERATOR MAINTENANCE MANUAL PAGE 24 Alarms...
Страница 29: ...OPERATOR MAINTENANCE MANUAL PAGE 25 Browsing ECU Alarms...
Страница 30: ...OPERATOR MAINTENANCE MANUAL PAGE 26...
Страница 31: ...OPERATOR MAINTENANCE MANUAL PAGE 27...
Страница 32: ...OPERATOR MAINTENANCE MANUAL PAGE 28 3 4 5 Field Wiring Cabinet...
Страница 35: ...OPERATOR MAINTENANCE MANUAL PAGE 31 3 5 Generator Wiring Diagram...
Страница 40: ...OPERATOR MAINTENANCE MANUAL PAGE 36...