OPERATOR & MAINTENANCE MANUAL
PAGE
‐
34
When
building
the
foundation,
specific
attention
needs
to
be
paid
to
the
following:
The
generator
base
must
be
isolated
from
the
building
foundation.
Depth
and
width
to
meet
the
basic
requirements.
Foundation
must
be
strong
enough
to
take
the
impact
and
running
force
of
the
machine.
Ensure
that
no
vibration
is
transmitted
to
the
building
foundation
when
the
unit
starts.
Ease
of
maintenance
and
servicability
operations.
When
calculating
the
length
L
and
width
B
of
the
base
allow
an
additional
100
‐
300mm
on
each
side.
The
base
should
be
higher
than
engine
room
floor
by
20
‐
300mm.
Mounting
the
Generator
The
generator
is
mounted
on
a
steel
‐
base
tank
that
provides
adequate
support.
Vibration
isolators
are
recommended
between
the
base
tank
and
the
foundation
to
provide
stable
operation
and
avoid
installation
damage.
Bolting
the
generator
directly
to
the
floor
or
foundation
can
result
in
excessive
noise
and
vibration,
and
possible
damage
to
the
generator
and
floor
foundation.
Mount
the
generator
on
a
substantial
and
level
base
such
as
a
concrete
pad.
Use
20mm
anchored
mounting
bolts
to
secure
the
vibration
isolators
to
the
base
tank
using
flat
or
bevel
washers
and
a
hexagonal
nut
for
each
bolt.
The
isolators
should
be
located
as
shown
on
the
generator
outline
drawing.
Incorrect
installation
or
service
can
result
in
severe
personal
injury
or
death,
and/or
equipment
damage.
Only
qualified
service
personnel
should
be
allowed
to
perform
electrical
and
mechanical
component
installation.
Never
install
the
genset
near
combustible
materials.
Locate
the
genset
such
that
combustible
material
can
not
accumulate
under
the
machine.
The
possibility
exists
of
fire
or
explosion,
causing
damage
to
the
equipment
and
or
severe
bodily
harm
or
even
death!
Содержание S10KS
Страница 1: ...PROMAC LEADING THE WAY OPERATOR MAINTENANCE MANUAL...
Страница 2: ...S10KS GENERATING SET OPERATOR MAINTENANCE MANUAL Edition A A Date 5 May 2011...
Страница 16: ...OPERATOR MAINTENANCE MANUAL PAGE 12 3 3 Generator Layout and Major Components...
Страница 18: ...OPERATOR MAINTENANCE MANUAL PAGE 14 3 4 Control Cabinet and Panel 3 4 1 Control Cabinet...
Страница 20: ...OPERATOR MAINTENANCE MANUAL PAGE 16 3 4 2 Control Panel...
Страница 28: ...OPERATOR MAINTENANCE MANUAL PAGE 24 Alarms...
Страница 29: ...OPERATOR MAINTENANCE MANUAL PAGE 25 Browsing ECU Alarms...
Страница 30: ...OPERATOR MAINTENANCE MANUAL PAGE 26...
Страница 31: ...OPERATOR MAINTENANCE MANUAL PAGE 27...
Страница 32: ...OPERATOR MAINTENANCE MANUAL PAGE 28 3 4 5 Field Wiring Cabinet...
Страница 35: ...OPERATOR MAINTENANCE MANUAL PAGE 31 3 5 Generator Wiring Diagram...
Страница 40: ...OPERATOR MAINTENANCE MANUAL PAGE 36...