53
12. Specification
Part number
K-ECK96
AC200V
~
230V±10% 50/60Hz
(
Automatic switching
)
Input
Power supply
Inrush current 50A or less
(
For initial 1 cycle
)
*1
Control method
Sine wave PWM control
Capacity of control rating
12.0A
(
For continuous driving. Rating for short time driving of 30 min or less is 14.0A
)
Frequency setting
30.0
~
200.0Hz (In case that carrier frequency is 10KHz or 14 KHz)
30.0
~
250.0Hz (In case that carrier frequency is 20KHz)
Output
Voltage setting range
0
~
200V
*2
Service power supply
DC24V 100mA (max)
Constant voltage function
Fluctuation of output voltage ±3% or less for the fluctuation of power supply voltage of ±10%
*3
Constant amplitude function
Signal of vibration sensor is fed back and amplitude is made to be stabilized.
Amplitude variation of ±10 % at the time when feedback is OFF, is controlled within ±3
%
*4
External control input
Drive and stop are possible by external signal (NPN/PNP open collector connection is possible)
Overflow control
Driving/Stopping by sensor signal is possible.
(
With timer function: ON 0.0
~
60.0 sec, OFF 0.0
~
30.0 sec
)
Drive instruction output
Non-voltage contact (linked to parts feeder) open/close capacity: AC250V 0.1A or less
Overload protection
Derating function of output voltage by setting current rating of load
Adaptiv
e funct
io
n
*5
Others
Various protection functions such as soft start, soft stop, short-circuit are installed.
Fuse
10A [Fuji Terminal Industry Co., Ltd. FGBO
φ
5.2×20 or the equivalent]
Noise immunity
1000Vp (Pulse width 1
μ
sec, by noise simulator)
Ambient temperature, humidity
0 to +40
℃
, 35
~
85
%
RH (No condensation allowed)
Protection structure
IP 20
Ambient atmosphere
(
Contamination level
)
Contamination level
Ⅱ
, Height: 1000m or less
However, there must not be corrosive gas. The substances giving trouble to electronic parts,
resins, and sheet metals such as awful dust, water, oil and solvents must not splash.
Mass
About 3.5kg
Applicable vibration main body
Only for G63
※
Leak current and earth leakage breaker
When you install an earth leakage breaker, please select the one of 200mA or more for the sensible current.
It is
because there is a leakage current of a high harmonic wave to the earth in the controller of the inverter method. Although
the leakage current of the controller during driving is about 1mA, the vibration main body changes depending on the
driving condition. Therefore it should be about 10mA/unit as a standard.
*1
Please note controller’s inrush current when you install a protection equipment such as an earth breakage breaker.
Please select the one of an appropriate current rating from the characteristic graph of the breaker so that the breaker
does not work with the inrush current. Moreover, when plural controllers are connected, the inrush current also
becomes larger. When number of controllers increase, please devise measures such as using plural breakers or
turning on the power source staggering the time.
*2
It is for the power supply voltage of 200V or more. When the power supply voltage falls, the maximum output voltage
is limited by the power supply voltage.
*3
The output voltage stability level is a value when the setting of the output voltage is 60-170V.
*4
As the constant amplitude performance changes according to the setting conditions of the vibration main body, it is not
a guaranteed value. Moreover, please note that it is not possible to follow the swift speed change (incl. drive stopping)
as the responsive performance becomes slow.
*5
Various adaptive functions are installed besides the items shown. Please refer to P.5 for details.