17
*
1
Wiring method when controlling with PNP transistor output
When controlling by the PNP transistor,
please connect the output (collector) side of
the PNP transistor to +V terminal, and the
terminal X1 to the common line (0V) side of
the controlling equipment. The current of
about 7mA flows under the control with 24V
because internal resistance of 3.3k
Ω
is
connected.
Your 24V power supply is used in case of
the PNP control.
It is possible to control similarly even by the
relay contact instead of the transistor.
The selection of the logic of the driving or
the stop at the short-circuit can be selected
by the function J02.
*
2
Wiring method when connecting to the separately placed hopper
①
Connect the separately placed hopper to
the terminals of earth bar 1 and 2.
②
Connect the level switch of the separately
placed hopper to between the terminals
24V-+V.
③
Insert the pilot signal (Y1C, Y1A) of the
controller for bowl feeder into between
terminals X1-0V.
④
Use data of function J02 by setting it as 1
(between terminals X1-0V [ON when
short-circuited]).
In the above-mentioned connection, the separately placed hopper drives only when the bowl
feeder is driving and also the level switch is ON (short-circuited between terminals 24V-+V). The
current of DC24V/7mA flows in the level switch.
*
1 Please refer to the operation manual of the separately placed hopper.
*
2 Please refer to the previous page for the terminal X1-0V (external control).
Your control circuit
0V
X1
24V +V
制御用
ケ
ーブ
ル
24V
ジャンパ1
3.
3k
24V
ジャンパ2
Jumper 1
Jumper 2
Control cable
制御用ケーブル
0V
X1
24V +V
3.
3k
24V
補助ホッパ付属の
レベルスイッチを
24V-+V間に接続
する
レベラ
Control cable
Leveller
Connect the level switch
attached to the separately
placed hopper to between 24V -
+V terminals.