37
<
List of H group functions
>
H
№
Name & Set range
(
Initial value is underlined
)
Change
during
driving
Record
of set
value
H00
Selection of functions of IN1 input
0:Driving with High input
1:Driving with Low input (reverse)
2:Separate IN1 (reverse) from
driving condition
Can
H01 ON delay timer 1
0.0~60.0 (Sec.)
Can
H02 OFF delay timer 1
0.0~30.0(Sec.)
Can
H03 Impossible of choice
―
H04 Impossible of choice
―
H05 Impossible of choice
―
H06 Soft start time
0.0~5.0(Sec.)
Initial value 0.5
Can
H07 Soft stop time
0.0~5.0(Sec.)
Initial value 0.3
Can
H08
Use of work shortage timer
0: Not used
1:Detected by IN1 signal
Can
H09
Work shortage detection time
1.0~120.0(Sec.)
Initial value 10.0
Can
H10
Work shortage reset time
0.1~30.0(Sec.)
Initial value 1.0
Can
H11 Impossible of choice
―
H12
Frequency of speed 1
30.0~200.0(Hz)
*1
Initial value 70.0
Can
H13
Voltage of speed 1
0~200(V)
Initial value 100
Can
H
№
Name & Set range
(
Initial value is underlined
)
Change
during
driving
Record
of set
value
H14
Frequency of speed 2
30.0~200.0(Hz)
*1
Initial value 70.0
Can
H15
Voltage of speed 2
0~200(V)
Initial value 100
Can
H16
Frequency of speed 3
30.0~200.0(Hz)
*1
Initial value 70.0
Can
H17
Voltage of speed 3
0~200(V)
Initial value 100
Can
H18
% speed of speed 1
0~100(%)
Initial value 50
Can
H19
% speed of speed 2
0~100(%)
Initial value 50
Can
H20
% speed of speed 3
0~100(%)
Initial value 50
Can
H21 Impossible of choice
―
H22
Setting of gain
0~200
Initial value 150
Can
H23
Setting of MAX. % speed
30~100(%)
Initial value 90
Can
not
H24 Impossible of choice
―
H25
Scaling
40~100
Initial value 70
Can
*
1
Only when 0 is selected with J11, variability up to
250.0Hz is possible.
.
*
2
Only when J06 is 0, change is possible.