36
(2) List of functions
There are two kinds of functions, J group that mainly sets functions and H group that mainly sets the data. Please
refer to “Contents of functions” of P. 41~ for the detail of each function.
Initial values at the time of shipment are underlined.
<
List of J group functions
>
J
№
Name & Set range
(
Initial value is underlined
)
Change
during
driving
Record
of set
value
J00
Operation lock
0: Operation lock OFF
1: Operation lock ON
Can
not
J01
Setting of current rating[A]
Set range:0.5
~
14.0
*1
Use range: 2.0
~
12.0
Initial value: 10.0[A]
Can
not
J02
Selection of driving method
0: External c Sensor
1:Reverse of external c
Sensor
2: Panel control
3: Panel c Sensor
Can
J03
Selection of JOG driving method
0: Do not make JOG operation
1: Accept JOG operation
Can
J04
Setting of F-V curve
F: Full wave type vibration main body
H:Half wave type vibration main body
P: Exclusive for G63
(
ECB96 interchangeable
)
C:
HF10 and others (High frequency system)
0~17 (Others)
Can
not
J05
Selection of constant amplitude control
0: Constant voltage control
1: Constant amplitude control
2:Impossible of choice
3: Implementation of calibration
Can
not
J06
Setting of driving condition
0: Manual setting
Set/change H23 data manually
1:Light weight high speed driving
Set at 100% of max. speed
2:Light weight medium speed driving
Set at 90% of max. speed
3:Heavy weight medium speed driving
Set at 80% of max. speed
4:Light weight low speed driving
Set at 65% of max. speed
5:Heavy weight low speed driving
Set at 50% of max. speed
Can
not
J№
Name & Set range
(
Initial value is underlined
)
Change
during
driving
Record
of set
value
J07 Not
used
―
J08 Not
used
―
J09
Display of error history
Displaying latest error data
(Content of protection function
behaviors) up to three
―
J10
Setting of initial value
(All clear of memory)
0:Normal operation mode
1:Rewriting the memory into the
initial value
Can
not
J11
*2
Change of carrier frequency
*
0:20kHz
1:14kHz
2:10kHz
Can
not
J12
Selection of functions of EM
terminal
0:Contact point is “Close” at the
time of problem
1:Contact point is “Open” at the
time of problem
2:
Contact point is “Close” for work
shortage
3:
Contact point is “Close” when LIMIT
lamp lights up or overload warning is ON
4:
Contact point is “Close” during driving
5:
Contact point is “Close” when driving
preparation is completed
Can
not
*
1
Only when J11 is 2, useable up to 14.0A
*
2
Please note that frequency variable range or setting
range of current rating changes by selection of J11.