RD 160.iCare+.OPM.ENG.V16 04.27.2020
p. 14
ENG
By default, instrument standard setting is “internal spray”. As illustrated in Fig. 28, to set external or without spray
instrument:
•
Press “Spray” key and the key corresponding to the position of the instrument simultaneously
•
To indicate that internal spray is disabled, the corresponding indicator is now illuminated
Fig.28– Without spray setting
If the internal spray is disabled by mistake or the internal spray is blocked, the unit detects it and will alert you. For
instance, this may occur in the following scenarios:
•
An instrument has been selected as an “external spray instrument” (but in reality, the instrument has an
internal spray)
•
An instrument that has been installed with external spray without using the button “ext W/O”
•
An instrument which has been installed which has a blocked internal spray channel
In such a case the iCare+ will alert you to the issue:
•
Unit will abort the cycle
•
“Air warning Indicator” LED will blink
•
Unit will emit an audible alert
•
The position of the instrument is shown using blinking indicators (oil indicator and/or ext-WO).
Fig.29– Warning
To restart the unit:
•
First open the door
•
Remove the instrument (to reduce the remaining pressure)
•
Reconnect the instrument
•
Then close the door.
If the problem happens again:
•
Remove the handpieces
•
Push the key “Start” to interrupt the cycle.
•
Check the instruments for possible blocked channels.