Single Connections
•
25
3.7 Alarm Signal ALM
The alarm signal ALM is used to indicate the alarm status from the servo
driver. The relative signal name, pin number and axis number are shown in
the following table.
CN2 Pin No
Signal Name
Axis #
9
ALM1
27
ALM2
59
ALM3
77
ALM4
The input circuit of alarm circuit is shown in the following diagram. The ALM
signals are usually from servomotor drivers, which usually provide open
collector output signals.
The external circuit must provide at least 5 mA
current sink capability to drive the ALM signal active. For more details of
the ALM operation, please refer to section 4.2.2.
To PCL6045
R
CN2
Inside PPCI7443
EX+5V
If = 12mA Max.
If = 5mA Min.
ALM
Содержание PPCI7443