144
•
Function Library
B_7443_auto_home_search(ByVal AxisNo As Integer, ByVal StrVel As
Double, ByVal MaxVel As Double, ByVal Tacc As Double, ByVal
ORGOffset As Double)As Integer
@ Argument
AxisNo: axis number designated to configure and perform home returning
home_mode: stopping modes for home return, 0~12
(Please refer to section 4.1.8)
org_logic: Action logic configuration for ORG signal
org_logic=0, active low;
org_logic=1, active high
EZ_logic: Action logic configuration for EZ signal
EZ_logic=0, active low;
EZ_logic=1, active high.
ez_count: 0~15 (Please refer to section 4.1.8)
erc_out: Set ERC output options.
erc_out =0, no erc out;
erc_out =1, erc out when homing finish
StrVel: starting velocity of a velocity profile in unit of pulse per second
MaxVel: starting velocity of a velocity profile in unit of pulse per second
Tacc: specified acceleration time in unit of second
ORGOffset: The escape pulse amounts when home search touching the
ORG singal
@ Return Code
ERR_NoError