122
•
Function Library
@ Argument
AxisNo: axis number designated to configure pulse Input/Output.
pls_outmode: setting of command pulse output mode
Value Meaning
0
OUT/DIR
OUT Falling edge, DIR+ is high level
1
OUT/DIR
OUT Rising edge, DIR+ is high level
2
OUT/DIR
OUT Falling edge, DIR+ is low level
3
OUT/DIR
OUT Rising edge, DIR+ is low level
4
CW/CCW
Falling edge
5
CW/CCW
Rising edge
pls_iptmode: setting of encoder feedback pulse input mode
Value Meaning
0
1X A/B
1
2X A/B
2
4X A/B
3
CW/CCW
pls_logic: Logic of encoder feedback pulse
pls_logic=0, Normal low.
pls_logic=1, Normal high
Src: Counter source
Value Meaning
0
External Feedback
1
Command pulse
@ Return Code
ERR_NoError
Содержание PPCI7443