For NPK 2,500 to 15,000 ft. lb. class hammers
6. Pre-fill the grease line (
29
) before installing (see the grease line pre-filling section of
this manual, pages 38 and 39). Route the hose under the hammer swivel fitting and
connect to the grease outlet port (
18
) on the side of the grease pump assembly (FZ).
7.1. For units with SAE style joint fittings.
a. Disconnect the hammer hoses (m5 and m6) from the top bracket joint fittings
(m18a and m18b). Remove the existing adapter fittings (m16) and discard.
b. Install the special adapter tee fittings (a62) into the top bracket joint fittings
(m18a, m18b). Reconnect the hammer hoses (m5 and m6).