SMART6-L User Manual Rev 3
53
Factory Default:
log com1 rxstatuseventa onnew 0 0 hold
log com2 rxstatuseventa onnew 0 0 hold
log com3 rxstatuseventa onnew 0 0 hold
log icom1 rxstatuseventa onnew 0 0 hold
log icom2 rxstatuseventa onnew 0 0 hold
log icom3 rxstatuseventa onnew 0 0 hold
Field
Field
Name
ASCII
Value
Description
Field
Type
1
LOG
(ASCII)
header
-
This field contains the command name or the
message header depending on whether the
command is abbreviated ASCII or ASCII respectively
-
2
port
See
Table 11,
Detailed Serial Port
Identifiers
on page 54
Output port
(default = THISPORT)
Enum
3
message
Any valid message
name, with an
optional A or B suffix
Message name of log to output
Char [
]
4
trigger
ONNEW
Output when the message is updated (not
necessarily changed)
Enum
ONCHANGED
Output when the message is changed
ONTIME
Output on a time interval
ONNEXT
Output only the next message
ONCE
Output only the current message (default)
ONMARK
Output when a pulse is detected on the mark 1 input,
MK1I
5
period
Any positive double
value larger than the
receiver’s minimum
raw measurement
period
Log period (for ONTIME trigger) in seconds
(default = 0)
Doubl
e
6
offset
Any positive double
value smaller than the
period
Offset for period (ONTIME trigger) in seconds. To log
data at 1 second after every minute, set the period to
60 and the offset to 1 (default = 0)
Doubl
e
7
hold
NOHOLD
Allow log to be removed by the
UNLOGALL
command
(default)
Enum
HOLD
Prevent log from being removed by the
UNLOGALL
command