The thresholds used to determine the solution type (OPERATIONAL, WARNING or OUT_OF_BOUNDS),
can be specified using the UALCONTROL command. Refer to the
OEM6 Family Firmware Reference
Manual
(OM-20000129) for more information.
Figure 13, Steadyline UAL- Warning Limit Example
on page 27 and
Figure 14, Steadyline UAL - Out of
Bounds Example
on page 28 show an examples of Steadyline using the UAL mode.
Figure 13: Steadyline UAL- Warning Limit Example
A
Position type is OPERATIONAL.
Higher accuracy corrections are lost. The receiver changes to a lower accuracy solution.
Steadyline operates in Maintain mode while the solution accuracy remains within the Operational
limit.
B
The solution accuracy exceeds the operational limit. The position type changes to WARNING.
The Steadyline mode changes from Maintain to Transition.
C
The solution accuracy moves back within the operational limit. The position type changes to
OPERATIONAL.
The Steadyline mode remains in Transition mode.
D
The solution offset is removed.
The Steadyline mode changes from Transition to Maintain.
Operational
Limit
Warning
Limit
Operational
Limit
Warning
Limit
A
B
C
D