![NOVACAT V10 ED Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/novacat/v10-ed/v10-ed_translation-of-the-original-operating-manual_1710489035.webp)
- 35 -
1401_GB-ISObus Terminal_3846
ISOBUS TERMINAL
GB
Time out - Monitoring
If the front mower sensor is not reached within 6 seconds
after pressing the “Raise front mower or all mowers” key.
Diag
Causes:
- Defective sensor
- Defective line
Note:
When this report is displayed, the front
mower sensor S7 becomes inactive.
Immediate
measures:
- Check if the front mower has been activated
in the SET menu!
- Check sensor lines!
Warning: Cross conveyor is not in working
position!
Therefore it is impossible to fold mower together.
Diag
Remedy:
Bring cross conveyor into working position and then fold
mower together.
If warning still shows:
Causes:
- Defective sensor (S9, S10)
- Defective line
- Hydraulics are leaking
Diagnosing function
Monitoring the job calculator for
Operating voltage
Power supply sensor
Short circuit to earth or 12 V
Broken cable
Overload
With fault recognition
- The alarm mask is superimposed and an alarm tone
sounds
- The relevant symbol and the fault is displayed
Confirm a fault with the "ACK" key.
The diagnosing function can be switched off for each
individual channel until the next system start by using
the key
"T9"
.
Switch outputs
example: Y1 = Directional control valve,
raise
T9
Diag
Causes:
- Short
circuit
- Insufficient
power
- Valve not connected
Note!
Should a fault occur, every required
function can be manually established using
the emergency activation (see chapter
"Electro-hydraulics").
Sensor inputs (Example: Sensor power supply < 10V
Diag
Causes:
- Insufficient voltage to the job calculator
- Defective job calculator
Note!
The power supply alarms cannot be
switched off.