- 33 -
1401_GB-ISObus Terminal_3846
ISOBUS TERMINAL
GB
SET menu
T4 Navigating in the "Cross conveyor belt swivelling"
menu (F123)
T7 Navigating in the "Time-distance dependent
lowering/raising" menu
- Change over to mask (F8)
T9 Navigating in the "Side shift calibration" menu
- Change over to mask (F10)
T10 Navigating in the "Cross conveyor belt speed"
menu (F11)
Meaning of display:
a
Set machine type
a
Activate/deactivate front mower
a
Front mower working width
a
Delay between the lowering to working position and
the activation of the curved cut optimisation.
F8
a
a
a
a
Meaning of display:
a
Set time or distance dependent lowering/raising
Kph =
Distance-/speed dependent
sec = Time dependent
- When using the curved cut optimisation, you must
set here "km/h".
a
Speed signal from tractor available or not available.
a
Set the lowering delay between the front and the rear
mower. This value is also the delay for the curved
cut optimisation
d
Set the lifting delay between the front and the rear
mower.
Different values for (meter (m) or seconds (sec.)) The
values for (m) and (sec) are adjustable individually
and are used depending on the time setting or the
setting for distance dependent
a
lowering/lifting.
F9
T2
T3
T4
d
e
f
a
a
a
T2 Save value
T3 Calibrate position max. working width
T4 Calibrate position min. working width
Novacat V10
Meaning of display:
a
current tension of the angle sensor left/right
a
minimum calibrated tension left/right
a
maximum calibrated tension left/right
d
Display:Transmission of the steering signal from tractor
(tick = active / cross = inactive
e
Display "current steering lock". (For straight driving a
value of around 32128 must be displayed.
f
Setting value: "Delta maximum retraction of the mower
bar" deviation from the straight driving value above
which the mower bar is retracted to the maximum.
Must be adjusted function of the tractor (empirical value
between 150 and 350) If the value is set too high, one
strip will stay still when cornering despite the activated
cut optimisation.
Menu function:
A sensor swap is necessary to calibrate the angle
sensors. The function serves to memorize the voltage
level at end positions.
• For this the mower units must be in the field transport
position.
• Calibration procedure
- Press "Decrease working width" until both mower
units are against the inner stop.
- Press "Increase working width" until both mower
units are against the outer stop.
- Save
F10
a
b
Meaning of display:
a
Tick = Differing speeds between the left and right
cross conveyor belt (for mowing in contour lines)
Cross = Same speed for both cross conveyor belts
with the possibility of switching between two speeds.
F7
T7
T9
T10
T4
b
c
a
d
Содержание V10 ED