![NOVACAT V10 ED Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/novacat/v10-ed/v10-ed_translation-of-the-original-operating-manual_1710489027.webp)
- 27 -
1400_GB-Power Control_3843
POWER CONTROL
GB
Diagnosis function
In the event of a malfunction, the relevant alarm report is displayed and an acoustic alarm sounds.
Function keys:
... the particular alarm is suppressed until
the next system start.
... Confirm the defect. If the fault repeats
itself, another alarm will be set off.
Alarm reports:
Switching output malfunction (Example: Y13)
Causes:
- Short
circuit
- Insufficient
power
- Valve not plugged in
Sensor power malfunction (Example: Sensor
power supply < 12V)
Causes:
- Insufficient power at the job calculator
- defective job calculator
Warning: Cross conveyor not in working position!
Therefore impossible to fold mower together.
Remedy:
Bring cross conveyor into working position and then fold
mower together.
If warning still shows:
Causes:
- Defective sensor (S9, S10)
- Defective
line
- Hydraulics
leaking
Note!
When a malfunc-
tion occurs, every
required function
can be manually
switched by using
the emergency
operation (see
chapter "Elec-
tro-hydraulics")
Note!
Confirm a fault
with key [ACK]
Note!
The
diagnosis
function can be
switched off for
every single
sensor until the
next system start
by using the
function key F1
[Switch off]!
The alarms for the
power supply can-
not be switched
off!