SyncInterval
Variable Name:
docsIfCmtsSyncInterval
Set/Get Response/Status:
Number (Milliseconds)
Description:
The interval between CMTS transmission of
successive SYNC messages at this interface.
REFERENCE
Data Over Cable Radio Frequency Interface
Specification, Sync Interval.
UcdInterval
Variable Name:
docsIfCmtsUcdInterval
Set/Get Response/Status:
Number (Milliseconds)
Description:
The interval between CMTS transmission of
successive Upstream Channel Descriptor
messages for each upstream channel at this
interface.
REFERENCE
Data Over Cable Radio Frequency Interface
Specification, UCD Interval.
MaxServiceIds
Variable Name:
docsIfCmtsMaxServiceIds
Set/Get Response/Status:
Number
Description:
The maximum number of service IDs that
may be simultaneously active.