4-96
302693-B Rev 00
CMTS 1000 Installation Manual V1.2
Index
Variable Name:
lcScanIndex
Set/Get Response/Status:
Number
Description:
An ad-hoc index for defining the scanning
order for this table.
Control
Variable Name:
lcScanControl
Set/Get Response/Status:
RowStatus
−
active, notInService, notReady,
createAndGo, createAndWait, destroy
Description:
Controls the creation and deletion of rows in
this table. See RFC-1903 for definition of
enumeration.
FreqStart
Variable Name:
lcScanFreqStart
Set/Get Response/Status:
Number (Kilohertz)
Description:
The center frequency of the first channel to
scan in this range.
FreqEnd
Variable Name:
lcScanFreqEnd
Set/Get Response/Status:
Number (Kilohertz)
Description:
The center frequency of the last channel to
scan in this range. This may be higher or
lower than lcScanFreqStart.