4-134
302693-B Rev 00
CMTS 1000 Installation Manual V1.2
BpiCmtsTEKGraceTime
Variable Name:
docsBpiCmtsTEKGraceTime
Set/Get Response/Status:
Number (Seconds)
Description:
Grace time for the TEK in seconds. The CM
is expected to start trying to get a new TEK
beginning, TEKGraceTime, seconds before
the TEK actually expires.
BpiCmtsTEKExpiresOld
Variable Name:
docsBpiCmtsTEKExpiresOld
Set/Get Response/Status:
DateAndTime
Description:
Actual clock time for expiration of the oldest
active key for this TEK association. If this
TEK association has no active keys, then the
value is of the expiration date and time of the
last active key.
BpiCmtsTEKExpiresNew
Variable Name:
docsBpiCmtsTEKExpiresNew
Set/Get Response/Status:
DateAndTime
Description:
Actual clock time for expiration of the newest
active key for this TEK association. If this
TEK association has no active keys, then the
value is of the expiration date and time of the
last active key.