Working with the CallPilot server BIOS
Standard 1.06
224
CallPilot
5
While the server is restarting, remove the BIOS update disk from
the server’s floppy disk drive.
6
When the server has rebooted, continue with “To configure the
BIOS” on page 224.
To configure the BIOS
Note:
Only options that need to be changed from their defaults are
described below. As you perform this procedure, you should still
validate that all BIOS settings conform to the values listed in “BIOS
settings,” on page 217.
1
During the server startup and while the startup diagnostics still
appear on the screen, press F2 to display the Main menu screen.
2
Press BIOS Default (F9) to load the default BIOS settings.
Result:
You are prompted to confirm the settings.
3
Choose Yes, and then press Enter.
Result:
The Main menu reappears.
4
Use the right and left arrow keys to choose the Advanced screen.
Result:
A list of configuration sections appears.
5
Configure the sections as follows:
Boot-up Diag Screen: Enabled
Num Lock: ON
Sleep Button: Disabled
6
Use the right and left arrow keys to choose the Server screen.
Result:
A list of configuration sections appears.
7
Configure the sections as follows:
Assert NMI on PERR: Disabled
Assert NMI on SERR: Disabled
8
Use the right and left arrow keys to choose the Boot screen.
Содержание 703t
Страница 6: ...Standard 1 06 6 CallPilot...
Страница 8: ...8 CallPilot Publication history Standard 1 06...
Страница 12: ...Task List Standard 1 06 12 CallPilot...
Страница 16: ...Contents Standard 1 06 16 CallPilot...
Страница 64: ...Using Windows online diagnostic tools Standard 1 06 64 CallPilot...
Страница 76: ...Using serial port diagnostic tools Standard 1 06 76 CallPilot...
Страница 118: ...Using CallPilot system utilities Standard 1 06 118 CallPilot Figure 13 Legend Help tab...
Страница 144: ...Replacing basic chassis components Standard 1 06 144 CallPilot...
Страница 150: ...Replacing media drives Standard 1 06 150 CallPilot Figure 25 Hard drive installation overview G101771...
Страница 170: ...Replacing media drives Standard 1 06 170 CallPilot...
Страница 188: ...RAID operations Standard 1 06 188 CallPilot...
Страница 196: ...Replacing or adding voice processing boards Standard 1 06 196 CallPilot...
Страница 247: ......