Defining PLC Communications
Profinet, Ethernet/IP and Modbus TCP are natively supported and do not
require you to install a communication card.
S
Refer to
Connecting Profinet, Ethernet IP and Mod BUS/TCP
for
more information.
S
For all other communication cards, refer to documentation that came with
the communication kit for installation and setup instructions. You can also
get the appropriate instruction sheet for your communication card from
the BBconn Cloud Media Center.
Communication Kit Name
Kit Part
Number
Instruction Kit
Part Number
KIT,ACCESS,PB
FLEX,COMM,PROFIBUS
1129161
1129124
KIT,ACCESS,PB
FLEX,COMM,ETHERCAT
1129162
1129293
KIT,ACCESS,PB
FLEX,COMM,CCLINK
1129163
1129294
KIT,ACCESS,PB
FLEX,COMM,SERCOS III
1129164
1129295
KIT,ACCESS,PB
FLEX,COMM,DEVICENET
1129165
1129296
KIT,ACCESS,PB
FLEX,COMM,POWERLINK
1129166
1129297
KIT,ACCESS,PB
FLEX,COMM,CCLINK IE
1129167
1129298
1. Select Specific Network and do the following to continue:
S
For Profinet, enter the Profinet Station Name - the Profinet device name.
The default name is
pbflex-pnio.
S
The Profinet station name must follow these guidelines:
‐
Can contain letters and numbers
‐
Letters must be lower case
‐
Can contain a hyphen (-) or a period (.)
‐
Cannot begin or end with a hyphen (-)
‐
Cannot begin with the character string "port-xyz" (x, y, z = 0 to 9)
‐
Cannot have the form of an IP address n.n.n.n (n = 0 - 255)
2. When done, press
<
to return to the
Network Settings
menu or
to
return to the
Home
screen.