System Settings
Heat Schedule
OLED User Interface
83
Part 1128351_02
E
2020
Nordson Corporation
Setting Up Heat Schedule
Use the Heat Schedule to set up
a daily or weekly schedule
to automatically
switch the heaters On or Off and to automatically enter and exit Setback.
1. Press the
on the Navigation pad to
Enable
Heat Schedule.
2. Select
Add a Heat Event,
press
>
then
do the following:
S
Press
to select which day or days of the week you want to set up a
heat schedule. When done, press the Down key to the bottom of the
list and select
Done
.
S
Select
Heaters On Time,
then press
>
,
and enter the time you want
the Master Heater control to switch On. For 12-hour clock, use the
Up/Down key to toggle between AM and PM. Press
to continue.
S
Select
Heaters Off Time,
then press
>
,
and enter the time you want
the Master Heater control to switch Off. For 12-hour clock, use the
Up/Down key to toggle between AM and PM. Press
and select
Done.
Press
<
two times to return to the Heat Schedule menu.
3. Select
Add a Setback Event,
press
>
then
do the following:
S
Press
to select which day or days of the week you want to set up a
heat schedule. When done, press the Down key to the bottom of the
list and select
Done
.
S
Select
Enter Setback Time,
then press
>
,
and enter the time you
want the Master Heater control to switch On. For 12-hour clock, use
the Up/Down key to toggle between AM and PM. Press
to
continue.
S
Select
Exit Setback Time,
then press
>
,
and enter the time you want
the Master Heater control to switch Off. For 12-hour clock, use the
Up/Down key to toggle between AM and PM. Press
and select
Done.
Press
<
two times to return to the Heat Schedule menu.
4. Press
to return to the
Home
screen.
NOTES:
S
Maximum number of event pairs is 6. You must enter an on/off times for
each Heat or Setback Event.
S
Heat and Setback Events cannot overlap each other.
S
A Setback Event must be contained within a Heat On/Off Event.
S
You can have multiple Setback Events within a single Heat Event.
S
If you remove a Heat Event, then all Setback Events contained within that
Heat Event are automatically deleted as well.
S
Heat or Setback Events cannot cross into the next day.