System Settings
Automatic System Setback
Temperature Settings
Setback Settings
OLED User Interface
51
Part 1128351_02
E
2020
Nordson Corporation
Defining Automatic System Setback
Use Automatic Setback to allow the melter to enter into Setback mode based
on the user-defined time of inactivity based on one of the following:
S
A hose/applicator # is assigned to an input. The melter will enter into
Setback if that assigned applicator is not dispensing adhesive for the
amount of time you define.
S
Fill system (optional for tank system configurations). The melter will enter
into Setback if the fill system is not activated for the amount of time you
define.
Once the system is in Setback, you can also define when you want the
Master Heater Control to switch Off, thereby preventing the adhesive from
charring or degrading.
1. Press the
on the Navigation pad to toggle
Automatic System Setback
to Enabled or Disabled. The default is Disabled.
2. Select
Automatic System Setback Source
and press
>
to make your
selection. When done, press
.
S
Fill - is available for Melt-on-Demand configured systems, or tank
versions with the optional Fill system.
S
I/O - you must assign
Automatic Setback
to an input and connect it to a
parent machine controlling the use of the applicator.
3. Select
System Setback Delay
and enter the amount of time to elapse of
inactivity before going into Setback. The default is 60 minutes, minimum
is 1 minute, the maximum is 1440 minutes. When done, press
.
4. Select
Auto Heaters Off Time
and enter the amount of time you want
the melter to remain in Setback before switching the Master Heater
Control Off. The default is 60 minutes, minimum is 1 minute, the
maximum is 1440 minutes. When done, press
.
5. Press
<
to return to the
Setback Setting
s menu or
to return to the
Home
screen.
NOTES:
S
Press the
Master control button to toggle Off (exit) Automatic
Setback.
S
While in Setback, the System Status indicator is Blue.
S
Press
on the OLED panel to clear and reset any Alert, Fault, or
Stop condition.