OLED User Interface
61
Part 1128351_02
E
2020
Nordson Corporation
2. Go to
Home | System Settings | Flow Settings
and select
Trigger
Settings.
Enter the following information
Setting
Description
Default
Trigger Polarity
Sets the polarity for correct product trigger operation. Use Light On
for normally open triggers, Dark On for normally closed triggers.
Dark
On
Trigger Type
Refer to the documentation that came with your trigger for this
information. This is also known as Trigger Sourcing.
PNP
Capture Mode
Upon detecting the leading edge of a product, the falling edge can
be either the beginning of the next product (Start-to-Start) or the end
of the current product (Start-to-End).
Start-to-
Start
3. Refer to
Using Teach Mode
to complete setting up Flow Monitoring.