Pressure
Runup
Pressure Settings
Pressure Mode
Pressure
Runup
Pressure Settings
Pressure Mode
OLED User Interface
39
Part 1128351_02
E
2020
Nordson Corporation
Pressure Runup Pressure Limits
Enter the maximum/minimum pressure you want the system to use for
production.
1. Select
Pressure Limit
, press
>
and enter the following information:
S
Maximum Pressure:
Pressure
Default
Minimum
Maximum
PSI
100
10
100
BAR
6.90
0.69
6.90
kPa
690
69
690
S
Minimum Pressure:
Pressure
Default
Minimum
Maximum
PSI
0
0
90
BAR
0
0
6.21
kPa
0
0
621
2. When done, press
<
to return to the
Runup Settings
menu or
to
return to the
Home
screen.
Pressure Runup General Settings
1. Select , press
>
and enter the following information:
S
Full Scale Line Speed:
Pressure
Default
Minimum
Maximum
Meter/
minute
100
1.5
300.2
Feet/
Minute
328
5
985
S
Zero Line Speed Pressure.
Setting
Description
Enabled
Allows the system pressure to remain at the
user-defined Minimum Pressure setting
Disabled
Allows the system pressure to drop to 0 (zero)
2. When done, press
<
to return to the
Pressure Control Settings
menu or
to return to the
Home
screen.