Pressure
Electronic
Pressure Settings
Pressure Mode
OLED User Interface
33
Part 1128351_02
E
2020
Nordson Corporation
Defining Manual and Electronic Pressure Monitor and Adjust Settings
You can order manual or electronic pressure adjust from the factory,
otherwise, you can order the appropriate kit. Contact your local Nordson
representative for more information.
S
For manual pressure monitoring, you will need part number 1128344.
S
For electronic pressure monitor and control, you will need part number
1128345.
S
For the complete pressure runup kit, you will need part number 1128908
Defining Manual Pressure Adjust Alert Settings
1. Select
Pressure Setting Range Alert
and press the
on the
Navigation pad to toggle
Pressure Setting Range Alert
to Enabled or
Disabled. The default is Enabled.
2. Select
Minimum Pressure Alert
, press
>
then enter the absolute
minimum system pressure before the melter enters into an Alert
condition. When done, press the
on the Navigation pad.
Pressure
Default
Minimum
Maximum
PSI
15
0
95
BAR
1.03
0
6.55
kPa
103
0
655
3. Select
Maximum Pressure Alert
, press > then enter the absolute
maximum system pressure before the melter enters into an Alert
condition. When done, press the
on the Navigation pad.
Pressure
Default
Minimum
Maximum
PSI
100
5
100
BAR
6.90
.34
6.90
kPa
690
34
690
4. When done, press
<
to return to the
Pressure Settings
menu or
to
return to the
Home
screen.
NOTE:
S
Press
on the OLED panel to clear and reset any Alert, Fault, or
Stop condition.