OLED User Interface
35
Part 1128351_02
E
2020
Nordson Corporation
3. Select
High Pressure Alert Threshold
, press
>,
then enter the amount
of pressure offset above the set point before the melter enters into an
Alert condition. When done, press the
on the Navigation pad.
Pressure
Default
Minimum
Maximum
PSI
(+)10 from
set point
(+)5 from
set point
(+)70 from
set point
BAR
(+)0.69
from set
point
(+)0.34
from set
point
(+)4.83
from set
point
kPa
(+)69 from
set point
(+)34 from
set point
(+)483 from
set point
4. When done, press
<
to return to the
Pressure Control Settings
menu or
to return to the
Home
screen.
Electronic Pressure Control Settings
1. Select
Minimum Pressure Set Point Range
, press
>,
then enter the
minimum pressure you want to use while in production. When done,
press the
on the Navigation pad.
Pressure
Default
Minimum
Maximum
PSI
10
10
100
BAR
0.69
0.69
6.90
kPa
69
69
690
2. Select
Maximum Pressure Set Point Range
, press
>,
then enter the
maximum pressure you want to use while in production When done,
press the
on the Navigation pad
Pressure
Default
Minimum
Maximum
PSI
70
20
100
BAR
4.83
1.38
6.90
kPa
483
138
690
3. Go to the next page to optionally define pressure alerts. Otherwise,
press
<
to return to the
Pressure Control Settings
menu or
to return
to the
Home
screen.