OLED User Interface
62
Part 1128351_02
E
2020
Nordson Corporation
Using the Teach Mode
Use the Teach mode to automatically calculate the
Target Add-On
and
Products to Average
values.
NOTES:
S
Make sure the
Adhesive Flow Monitoring
option is enabled. (
Home |
System Settings | Flow Settings)
S
Although not required, it is recommended that you calibrate the Flow
Meter. You must define the Product and Trigger settings.
S
The melter must be in a Run state with the pump enabled.
1. Start production from the pattern controller.
2. Go to
Home | Flow |
and select
Start Teach Mode.
The teaching process duration depends on how long it takes the system
to record either 8 grams of adhesive or 10 products, whichever is greater.
The system then calculates the Target Add-On value
3. Refer to the
Defining Adhesive Flow Monitoring Alarms
to complete
Flow Monitoring.