OLED User Interface
64
Part 1128351_02
E
2020
Nordson Corporation
Setting
Description
Default
Min
Max
Low Stop Threshold
How much lower the add-on weight
(mg) can be from the Target Add-On
value before a Stop alarm is
generated.
.3 * Target
Add on
.05 *
Target
Add on
.5 * Target
Add on
High Stop Threshold
How much higher the add-on weight
(mg) can be from the Target Add-On
value before a Stop alarm is
generated.
.4 * Target
Add on
.05 *
Target
Add on
.5 * Target
Add on
Stop Delay Count
The number of consecutive
out-of-tolerance products allowed
before the system considers them
defective and generates a Stop alarm
4
1
15
Monitoring and Viewing Adhesive Flow Output
Go to
Home | Flow
to view the following flow data:
Flow
Description
Total Products
Total products created since last reset.
Total Alarms
Combination of Alert and Stop alarms, as well as Over Flow and
Phase Errors generated since last reset
Defective Products
Total number of products, after meeting the Stop/Alert count
thresholds since last reset.
Adhesive Usage
Total amount of adhesive measured through the flow meter
Adhesive / Hour
Total amount of adhesive measured through the flow meter within the
hour.
Adhesive Usage
Total amount of adhesive measured through the flow meter