Hydraulic Section Repair
C 2-11
Part 1022914G03
E
2007 Nordson Corporation
Siphon Housing Assembly and Installation
1. See Figure C 2-10. Install the following into the siphon housing (18), in
order:
a. New white PTFE O-ring (17) (lubricate first with O-ring lubricant)
b. Siphon ball seat (16)
c. Large ball (15)
d. Cage (14)
2. Thread the siphon housing onto the pressure housing (12) and tighten
snugly.
14
15
16
17
18
12
Apply Parker O-Lube or
equivalent before installing.
Figure C 2-10 Siphon Housing Assembly and Installation
12. Pressure housing
14. Cage
15. Ball (large)
16. Siphon ball seat
17. O-ring (white PTFE)
18. Siphon housing