Pro-Meter V2K
5. Enable OPEN DISPENSE VALVE pushbutton.
Note:
If utilizing a Nordson Sealant Equipment dispense valve, the internal piston should be retracted
(moved away from the dispense tip).
The Pro-Meter V2K has four operating modes, Auto Shot, Auto Flow, Manual Shot, and Manual Flow.
Selection of these modes occurs via the
Dispense 1
Screen. However, Auto Flow mode is only available
when the Pro-Meter V2K is controlled by an outside robot (Interlock Mode).
Manual Mode
In manual mode, the system will fault out when the fault limit is reached. If PURGE WARNING TIME has
been set, the system will fault when the fault limit is reached. A purge cycle as opposed to a dispense cycle
will be run. The purge timer will then reset.
Manual Shot Mode
- When the dispense command is given, either by the foot switch or the DISPENSE
pushbutton on the
Dispense 1
Screen, the Pro-Meter V2K will dispense one complete stroke. The stroke
length is established mechanically. Refer to
Stroke Length Setup
(below) for additional information.
Manual Flow Mode
- The meter will continue to dispense and reload as long as the foot switch or the
DISPENSE pushbutton on the
Dispense 1
Screen is pressed.
Auto Shot Mode
- Auto Shot mode is similar to Manual Shot mode. However, this mode allows the meter to
dispense and reload multiple strokes, depending on the value established in the SHOTS PER CYCLE data
entry field on the
Stroke Setup
Screen. If the number entered into the SHOTS PER CYCLE field is
1
, Auto
Shot and Manual Shot modes will function identically.
Operating Modes
11