Pro-Meter V2K
period the operator is warned that they are approaching the PURGE FAULT TIME.
Return to the
Main Menu
Screen and then proceed to the
Dispense 1
Screen. Next, proceed to the
Purge
Control
Screen to setup the purge timer. When the PURGE TIMER pushbutton is turned OFF, the meter will not
purge or fault. The Pro-Meter V2K will remain operational unless some other fault interferes with operation.
When the PURGE TIMER is turned ON, the TIME LEFT TO PURGE will be displayed. While in Manual
Mode, the system will fault once the FAULT LIMIT is reached. A purge cycle as opposed to a dispense cycle
will be run. The purge timer will then reset.
PURGE CORD PIN LAYOUT
Wire Color
Description
Brown
Not used
White
Not used
Blue
Positive side of `Ok To Purge' Signal
Black
Negative side of `Ok To Purge' Signal
13
Содержание 7440272
Страница 20: ...APPENDIX A 20...