Specific Alarms and Auto Increment (continued)
Appendix B, RS-232C Connection Technical
Information (continued)
Command
Description
Command Format
Sample with Output
Set Unit
Alarms
Enables or disables the different
alarm settings for the controller
Host Format: 012345alrm
0 Input Alarm Enable (0 disable /
1Enable)
1 Input Alarm Latch (0 disable /
1Enable)
2 Pressure Alarm Enable (0 disable /
1Enable)
3 Pressure Alarm Latch (0 disable /
1Enable)
4 Heater Alarm Enable (0 disable /
1Enable)
5 Heater Alarm Latch (0 disable /
1Enable)
000000alrm [Enter]
Alarm Settings successful
101010alrm [Enter]
Alarm Settings successful
Feedback
Alarm Settings
Reads the current alarm settings
Host Format: falr
falr [Enter]
Alarm Status: 1= Enabled
0=Disabled
0 Enable Input Alarm
0 Latch Input Alarm
0 Enable Pressure Alarm
0 Latch Pressure Alarm
0 Enable Heater Alarm
0 Latch Heater Alarm
Set Heater
Fault Time
Sets the Heater Fault Time used to
trip a Heater Fault Alarm
Host Format: DDDhtft
Where DDD is the desired time setting
in seconds
059htft [Enter]
Heater Fault Time=059
Miscellaneous
Command
Description
Command Format
Sample with Output
De-bounce
Operation
Enables or disables the de-
bounce option on foot pedal
initiate signals
Host Format: xdbnc
0dbnc Disables system de-bounce on the foot
pedal initiate signals
1dbnc Enables system de-bounce on the foot
pedal initiate signals
1dbnc [Enter]
****F/S Debounce ON ****
0dbnc [Enter]
****F/S Debounce OFF ****
System
Information
Returns the firmware version
of the ValveMate 9000
controller
Host Format: info
info [Enter]
7028693-VM 9000
V:001.001 1/1/14
System
Reboot
Performs a soft reboot
Host Format: boot
boot [Enter]
ValveMate 9000 Controller
78