Equipment-Specific Safety Labels and Tags
Maximum Air Pressure Caution
Caution symbol informing that the maximum air input pressure is 6.9 bar (100 psi). Excessive air input
pressure may damage the equipment.
Electrical Shock Warning
Warning symbol informing of the risk of electrical shock. Disconnect the power cord before removing
the electrical cover.
Burn Warning
Warning symbol informing of the risk of burns from a hot valve. Connect power to heated valves as
specified in the valve operating manual.
Equipment-Specific Safety Information
Safety Ground Connection
Nordson EFD controllers are designed with a three-position IEC 60320-C14 receptacle that connects the ground line
to the chassis ground. To minimize shock hazard, make sure your electrical power outlet and power cord have an
appropriate earth safety ground that is connected whenever you power up the controller.
If your power outlet does not have an appropriate ground connection, you must connect a safety ground to the
chassis grounding screw located on the rear panel of the unit. To connect the safety ground, complete the following
steps:
1. Connect a 16 AWG (1.3 mm) wire to the chassis grounding screw on the rear of the chassis using a toothed
grounding lug. The wire must have green insulation with a yellow stripe or must be noninsulated (bare).
2. Attach the opposite end of the wire to a permanent earth ground using toothed washers or a toothed lug.
AC Power Connection
• The power supply cord is used as the main disconnect device. Ensure that the power outlet is located near the
equipment and is easily accessible.
• Use only the supplied power cord.
• Use only on a circuit with a fuse or circuit breaker that is 20 A or less.
CAUTION
Nordson EFD Product Safety Statement (continued)
Burn warning
Maximum air
pressure caution
Electrical shock
warning
ValveMate 9000 Controller
11
www.nordsonefd.com [email protected]