Parameter
Range of Values
Description
MEM
00–99
Shows the current memory cell number. Refer to “Entering Memory
Cell Settings” for information on memory cells.
MODE
OFF, ON
OFF: Sets the pressure regulator output to zero (0).
ON: Enables the pressure regulator output. The pressure will be
regulated to the value entered for SET.
SET
0–100 (psi),
0–6.9 (bar), or
0–069 (kpa)
in intervals of 0.1 psi
Sets the pressure for the selected regulator.
ACT
—
Shows the actual pressure of the pressure channel.
ALARM
—
Refer to “Clearing Alarms.”
Setting Up Pressure Control
1. On the MAIN screen, press the F1 or F3 keys until
the PRESSURE screen appears.. The screen shows
both pressure control channels side by side.
2. Use the ARROW keys to highlight the parameter to
be changed. Use the following methods to change
a parameter:
• MEM and MODE: Press ENTER (
↵
) to change the
selection.
• SET: Press ENTER to change the selection by entering
a value, or press the INCREASE (+) or DECREASE (-)
key to adjust the value.
Refer to the “Pressure Control Parameters” table for an
explanation of each parameter.
Pressure Control Parameters
Setup (continued)
VM9000 Controller Key Legend
INCREASE (+) key
DECREASE (-) key
ENTER key
DISPENSE key
ARROW keys
,
ENABLE/DISABLE key
ValveMate 9000 Controller