Setting Up the General Purpose I/Os
1. On the MAIN screen, press the F1 or F3 keys until the
first GENERAL PURPOSE IO screen appears. The
GENERAL PURPOSE IO screens show the I/O channels
side by side.
2. Use the ARROW keys to highlight the parameter to be
changed. To access the second GENERAL PURPOSE
IO screen, keep pressing the down ARROW key.
3. Use the following methods to change a parameter:
• MEM and MODE: Press ENTER to change the
selection.
• TIME, DELY, ON, and OFF: Press ENTER (
↵
) to
change the selection by entering a value, or press
the INCREASE (+) or DECREASE (-) key to adjust the
value.
Refer to the “GENERAL PURPOSE IO Parameters”
table for an explanation of each parameter.
GENERAL PURPOSE IO screen, page 1
GENERAL PURPOSE IO screen, page 2
Setup (continued)
VM9000 Controller Key Legend
INCREASE (+) key
DECREASE (-) key
ENTER key
DISPENSE key
ARROW keys
,
ENABLE/DISABLE key
ValveMate 9000 Controller
38
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.