Check the Component Installation
1. Make sure:
• The air pressure to the controller is set to 4.8–6.9 bar (70–100 psi).
1
• The dispense initiate and I/O connections are wired correctly.
2
• The dispense valves and fluid reservoir are properly connected.
3
• The valves are set up and dispensing tips are properly installed.
4
2. Continue to “Setup” to enter controller settings.
5
Installation (continued)
Always depressurize a fluid reservoir before opening. To do this, slide the shutoff valve on the air line away from the
reservoir. If using an EFD fluid reservoir, open the pressure relief valve as well. Before opening the reservoir, check
the pressure gauge to verify that the pressure is zero (0).
On all EFD cartridge reservoirs, the unique threaded design provides fail-safe air pressure release during cap
removal.
CAUTION
1
2
5
3
4
ValveMate 9000 Controller
26