AIR IN Connection
NOTE:
Clean, dry, filtered factory air is required to
meet warranty.
1. Install the filter regulator (P/N 7002002) in the
plant air supply line.
2. Install the air fitting (P/N 7022198) in the filter
regulator output port.
3. Connect one end of the supplied 6-mm OD air
line tubing to the P/N 7022198 air fitting.
4. Connect the other end of the tubing to the
AIR IN connector on the back of the controller
by pushing it firmly into the connector until
it bottoms out. Make sure the line tubing is
inserted all the way into the fitting.
5. Set the pressure at the filter regulator to
4.8–6.9 bar (70–100 psi).
Fitting,
P/N 7022198
Filter
regulator,
P/N 7002002
AIR IN
connection
(6 mm)
EXHAUST Connection
The EXHAUST port expels air from the electronic pressure regulators.
Make sure the exhaust port is not restricted. If needed, connect air line
tubing to the quick-connect fitting route the exhaust air to a remote
location.
EXHAUST
connection
(6 mm)
Installation (continued)
ValveMate 9000 Controller
22