Parameter
Range of Values
Description
MEM
00–99
Shows the current memory cell number. Refer to “Entering Memory
Cell Settings” for information on memory cells.
MODE
OFF, ON, STDY, PULS
OFF: The driver channel is off and will ignore the initiate signal.
ON: The driver channel turns on for the number of seconds entered for
ON and turns off for number of seconds entered for OFF. The driver
immediately repeats the cycle for the number of cycles entered for
DCNT.
STDY: The driver stays on continuously until the initiate signal is
deactivated. The ON, OFF, and DCNT parameters display - - - -.
PULS: The driver continuously turns on and off (pulse) for the ON and
OFF times until the initiate signal is deactivated, at which point the
driver output turns off when ON is complete. DCNT displays
- - - -.
ON
0.0001–9.9999 [sec,
with a 100 µs resolution
(0.0001)]
The number of seconds the driver output turns on when an initiate
signal is activated.
OFF
0.0001–9.9999 [sec,
with a 100 µs resolution
(0.0001)]
The number of seconds the driver output turns off once the number of
ON seconds is complete.
DCNT
0001–9999 (cycles)
The number of times the driver channel repeats one ON and
OFF cycle.
SPHld
OFF, ON
When SPHld is ON, the driver output performs a spike-and-hold
operation for the spike time (20–250 ms) and then switches to the hold
voltage (5–24 V). Refer to “Entering Driver Spike and Hold Settings” to
enter spike time and hold voltage.
VOLTS
5–24 (V, in 1-V
increments)
The output voltage the controller supplies to the drivers. If SPHld is
OFF, this setting is the output voltage. If SPHld is ON, this setting is
the spike voltage. Refer to “Entering Driver Spike and Hold Settings”
to enter spike time and hold voltage
SHOT CNT
00000000–99,999,999
This parameter counts the number of cycles the driver channel is
activated. The SHOT CNT parameter increases by one for every cycle
the driver is on, not every initiate. Press ENTER to reset SHOT CNT to
00000000.
Setting Up the Driver Outputs (continued)
Driver Output Parameters
Setup (continued)
ValveMate 9000 Controller
35
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.