Entering Pressure Alarm Settings
1. On the MAIN screen, press F2 .
2. Use the ARROW keys to highlight PRESSURE
SETTINGS, then press ENTER.
3. Use the ARROW keys to highlight PRES ALM RANGE
or PRES ALM DELAY, then press ENTER.
• Pressure Alarm Range—if the actual pressure falls
above or below the range specified by this setting, a
pressure alarm is generated.
• Pressure Alarm Delay—the amount of time that the
actual pressure may fall above or below the pressure
alarm range before a pressure alarm is generated.
4. Use the INCREASE (+)/DECREASE (-) keys to change
the parameter value. The value must be within the
ranges shown below.
• Pressure Alarm Range: +/- 1–10 psi
(+/- 0.07–0.69 bar, +/- 7–69 kPa)
• Pressure Alarm Delay: 00–99 (sec)
5. Press F2 to save the changes and return to the MAIN
MENU.
6. Press F2 again to return to the MAIN screen.
7. Refer to “Setting Alarm Output Options” to enable /
disable and latch alarms.
Pressure System Alarm screen
To cancel changes at
any time and return
to the MAIN MENU,
press F3.