23
•
Cables labeled with
UP
go on the same side
as the hydraulic hoses on the
44963D
block.
44933D
44963D
Figure 25 – Valve Cable Connections
13.
Connect the CAN Node cable (
C02B
) to the
4-pin AMP plug on
C11
(
Figure 26
).
14.
Route the CAN Node cable (
C02B
) to the
roll sensors which are installed in
Section
4.5
. Follow existing cables and/or hydraulic
lines.
15.
Connect 4-pin AMP connectors on
C02B
to
the sensors.
16.
Connect the sensor branch cable (
C02
) to the
4-pin AMP plug on
C02B
.
17.
Route the sensor branch cable (
C02
) to the
wing and main sensors and connect to the
sensors. Follow existing cables and/or
hydraulic lines along the boom.
18.
Cable-tie the installed cables every 12 inches.
IMPORTANT:
Provide enough slack in all cables to account
for the movement of the main section, parallel
lift, and FOLDING boom movement.
Figure 26 – Cable Configurations: C11, C02
and C02B
Содержание UC4+ Raptor Pro 1200
Страница 10: ...7 Figure 3 Hydraulic Components ...
Страница 15: ...12 Figure 9 Sensor Serial Number Installation Location 3 SENSOR SYSTEM 5 SENSOR SYSTEM ...
Страница 29: ...26 5 3 ITEM C02B 44664 CABLE UC4 CAN NODE DUAL 5 4 ITEM C03 44656D CABLE VALVE VARIABLE RATE DT ...
Страница 30: ...27 5 5 ITEM C04 44651 VALVE EXTENSION CABLE 5 6 ITEM C10 44650 33 POWER CABLE UC3 BOOM RP1 ...
Страница 31: ...28 5 7 ITEM C12 44658 11 BC RP1 VALVE CABLE ...