15
4.5.1 Boom Frame Roll Sensor Mounting
1.
Use the supplied hardware to mount the
boom frame roll sensor (
E04
) as shown in
Figure 15
.
When mounting the boom frame roll sensor
follow these guidelines:
a)
To prevent bending the bracket, ensure
bolts are placed as close together as
possible (minimize
C
in
Figure 15
).
b)
Be sure to use the roll sensor without the
temperature probe (
E04
).
c)
When the boom is centered (not rolled
over) the roll sensor should be level with
respect to the sprayer chassis.
d)
It is best to mount the roll sensor to the
left hand trapeze link (when looking
from the rear of the sprayer).
e)
The
roll
sensor
AMP
(circular)
connector
MUST exit towards the
right hand wing
(when looking from
the rear of the sprayer).
Figure 15 – Boom Frame Roll Sensor
Mounted to a Trapeze Link
2.
Cable-tie the sensor connector to the frame
with enough slack to allow the link to rotate.
Make sure the bracket does not collide
with any parts of the sprayer when the
boom rotates. Also ensure there is
enough slack to allow the roll sensor to
rotate.