10
4.3 W
ING
S
ENSOR
I
NSTALLATION
1.
Assemble the Breakaway Sensor Mounting
Brackets (
B11
) as show in
Figure 4
and
Figure 5
.
Figure 4 – Breakaway Sensor Bracket
Exploded View
Figure 5 – Breakaway Sensor Mounting
Bracket Assembly
To assemble the breakaway sensor bracket:
a)
Assemble the bolt and nut into the collar.
b)
Grease the bottom edge of the collar and
the angled tube of the base.
c)
Place the collar onto the angled tube of
the mounting base.
d)
Install the spring between the collar and
the upper ring of the base.
e)
Insert tube through assembly and tighten
the collar
2.
Mount the sensor bracket onto the boom.
If possible, mount the sensor brackets
while the booms are in their folded
position to ensure that they will not
interfere with anything when the boom
is folded for transport.
3.
The sensor mounting brackets can be
installed with the mounting base behind
(
Figure 8
) or in front of the tube (
Figure 6
).
Mounting the sensor bracket to the
break-away section of the boom may
cause the boom to drop suddenly as a
break-away occurs. This will occur on
break-away sections which lift as they
break away.
For optimal boom tip protection, it is
recommended that the sensor be
mounted within approximately two
feet (60cm) of the boom tip.
Please refer to the UC4+ Spray Height
Control system warranty at the end of the
UC4+ Spray Height Control Operator’s
Manual
(
M01
) for implications.
4.
Mount the NORAC UC4+ ultrasonic sensor
(
E02
) into the sensor brackets. The sensors
should be oriented forward (ahead) of the
boom (see
Figure 6
and
Figure 8
).
When installing the UC4+ sensors
(E02), start with the smallest serial
number
on
the
left
hand
side
proceeding to the largest serial number
on the right hand side (Figure 9).
5.
Sensor cables should run through the
mounting bracket tube and then behind the
member the bracket is mounted onto. Cable-
tie the connector in place. The cable must
Содержание UC4+ Raptor Pro 1200
Страница 10: ...7 Figure 3 Hydraulic Components ...
Страница 15: ...12 Figure 9 Sensor Serial Number Installation Location 3 SENSOR SYSTEM 5 SENSOR SYSTEM ...
Страница 29: ...26 5 3 ITEM C02B 44664 CABLE UC4 CAN NODE DUAL 5 4 ITEM C03 44656D CABLE VALVE VARIABLE RATE DT ...
Страница 30: ...27 5 5 ITEM C04 44651 VALVE EXTENSION CABLE 5 6 ITEM C10 44650 33 POWER CABLE UC3 BOOM RP1 ...
Страница 31: ...28 5 7 ITEM C12 44658 11 BC RP1 VALVE CABLE ...