18
44933D
Figure 19 – Valve Block Assembly
4.6.2 Valve Mounting
1.
Mount the NORAC valve (
V01
) on the
sprayer using the valve mounting bracket
(
B10
).
2.
As shown in
Figure 20
, screw short side of
the threaded rods into the bottom of the valve
block at least 3/8". The valve mounting holes
are drilled and tapped 3/8 NC-1" deep.
3.
Tighten the Hex nuts to hold the rods.
4.
Put the mounting bracket on the other side of
the tube and tighten with the spring washers
and the Hex nuts.
5.
Cut excess off of the rods, if necessary.
If using bolts, the bolts should thread
into the valve block at least 3/8". The
valve mounting holes are drilled and
tapped 3/8 NC-1" deep. The rule of
thumb for bolt length is 1-1/2" longer
than the tube size.
The
recommended
location
for
mounting the valve block is on the
bottom cross member of the main
boom section. It is on the front of the
boom across from the sprayer valve
block (Figure 21).
You
must
ensure
no
hydraulic
components will interfere with any
sprayer parts or be pulled tight at any
time.