50
- FORM NO. 56043129 - SR 1900
SOLUTION SYSTEM
TROUBLESHOOTING GUIDE
Troubleshooting Guide
Symptom
Misting pump will not work
Part B: Electrical Load Circuit
Note 1: Do all testing with the key switch ON, misting solution tank not empty, main broom
lever lowered, drive pedal activated in Fwd or Rev and the M4 misting pump’s control switch
S26 turned ON.
Note 2: Before T.S.check the continuity of the pump’s circuit breaker CB 7 (10A), reset or
replace if defective.
Note 3: Check for plugged misting nozzles clean if needed.
Misting pump will not
work
Test continuity of the
CB7(10A) circuit
breaker & its wiring.
Repair or replace
defective parts.
Test for 12V’s @ the M4
misting pump wires (+
Gra/Orn & - Blk).
Test for (+)12V’s
@ the K6 Blu wire
to battery ground.
Do you have
12V’s?
Replace the
defective K6 misting
pump relay
Repair or replace the M4
misting pump.
Test for (+)12V’s
@ the K6 Gra/Orn
wire to battery
ground. Do you
have 12V’s?
Yes
No
Yes
On the (+) Gra/Orn
& (-) Blk M4 pump
wires check for an
open circuit.
Repair or replace
the defective wire
Yes
No
No