Troubleshooting Guide
Symptom
Shaker motor will not run
Part A: Electrical Control Circuit
Note: Do all testing with the key switch ON, then press the control panel shaker switch to
activate turn on the shaker motor (shaker runs for approximately 15 seconds).
See hydraulic shaker motor
troubleshooting section B
Replace the A2
control box assy.
Does the shaker
motor run ?
Ribbon pins test
open replace the
touch pad switch
panel
* Ribbon connector see Electrical System Figure 1 for detail pin call-outs.
Check K3 relay
coil wiring
continuity (Vio &
Yel/Red), repair
if faulty
Is there 12V’s at
the K3 coil ?
Test for 12V’s @
the K3 shaker
motor relay coil,
wires (+) Vio &
(-) Yel/Red.
Test for Neg.
(-)12V’s@
the K3
Yel/red wire
to Bat (+).
Press & hold
shaker motor
switch and
check for
continuity @
the ribbon
connector (*)
for pins J3-1 &
J3-11 on the
A2 control box.
Shaker motor
will not run
Yes
Yes
No
No
No
No
SWEEPING SYSTEM
TROUBLESHOOTING GUIDE