Important health and safety information
XT V 160 X-ray System
XTM0011-F2
3
These include either the provisions of the Health and Safety at Work Act 1974 (UK
Regulations), or the Occupational Safety and Health Act (OSHA) as published in the
Code of Federal Regulations (USA), title 29, part 1910, and any additions or
amendments that may become legal requirements.
The personnel should also comply with the equivalent statutory requirements of their own
country.
4. Any operator performing routine maintenance on the X-ray system must be trained to
carry out these procedures.
Refer to the Operator Manual provided either physically or electronically with the X-ray
system for details of these procedures.
5. Ensure that the control console and monitor support arms are adjusted for comfortable
operator use and then firmly locked in position, where applicable.
Take advice on the safe use of computer and monitor equipment as provided by local
regulations.
6. Take care when loading and unloading samples from the system. Never overload the
manipulator. Repeated opening of the door and sample loading may lead to discomfort.
Customers should comply with Provision and Use of Work Equipment Regulations
(PUWER).
7. Noise emitted by the X-ray system is minimal. The level of noise will not exceed
an A-weighted pressure level of 70 dB (A).
8. The cabinet can be cleaned with a cloth dampened with water. Switch off and isolate
mains power before cleaning, and allow to dry before reconnecting. Take care when
cleaning as mechanical hazards are present.
1.5
Understanding the hazards
1.5.1
X-ray radiation
X-rays are ionising radiation. High doses of ionising radiation can cause lasting injuries,
disfigurement and (in extreme cases) death.
The X-ray system has been designed and built to United Kingdom Ionising Radiation
Regulation Standards (IRR 2017).
The system is certified by Nikon Metrology to emit less than one microsievert per hour
(1 µSv/h) on all external surfaces. Certification is provided with the system. There is no
significant X-ray radiation risk to users under normal operating conditions.
If the system is damaged, it must not be used and Nikon Metrology
must be contacted immediately. Nikon Metrology will then arrange for
an approved engineer to examine the system for radiation leakage
before it can be re-commissioned.
This does not replace the need for statutory radiation safety checks to be carried out at the
site in accordance with your regional or national legal requirements.
1.5.2
High voltages
The system contains high voltages. These pose no risk to users under
normal operating conditions.
Содержание XT V 160
Страница 1: ...X Tek X ray and CT Inspection XT V 160 X ray System Operator Manual XTM0011 F2 ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 22: ......
Страница 26: ......
Страница 32: ......
Страница 83: ...Maintenance XT V 160 X ray System XTM0011 F2 73 ...
Страница 90: ...Troubleshooting 80 XTM0011 F2 XT V 160 X ray System ...
Страница 93: ......