AD700E
7
General information
Important safety information
General Information and Ratings
Mechanical Installation
Operation
Parameters
Analog and Digital Input Macro
Configurations
Power Wiring
Chapter 9
P. 48
Chapter 10
P. 50
Modbus RTU Communications
Technical Data
Trouble Shooting
Chapter 11
P. 54
PREVIOUS VIEW
1/2
2 IMPOR
TANT SAFETY INFORMA
TION
2
2 IMPORTANT SAFETY INFORMATION
Please read the IMPORTANT SAFETY INFORMATION below,
and all Warning and Caution information elsewhere.
Danger: Indicates a risk of electric shock, which, if not avoided, could
result in damage to the equipment and possible injury or death.
This variable speed drive product (AD700E) is intended for professional incorporation into complete equipment or systems as part of a fixed
installation. If installed incorrectly it may present a safety hazard. The AD700E uses high voltages and currents, carries a high level of stored
electrical energy, and is used to control mechanical equipment that may cause injury. Close attention is required to system design and electrical
installation to avoid hazards in either normal operation or in the event of equipment malfunction. Only qualified electricians are allowed to install
and maintain this product.
System design, installation, commissioning and maintenance must be carried out only by personnel who have the necessary training and
experience. They must carefully read this safety information and the instructions in this Guide and follow all information regarding transport,
storage, installation and use of the AD700E, including the specified environmental limitations.
Do not perform any flash test or voltage withstand test on the AD700E. Any electrical measurements required should be carried out with the
AD700E disconnected.
Electric shock hazard! Disconnect and ISOLATE the AD700E before attempting any work on it. High voltages are present at the terminals and
within the drive for up to 10 minutes after disconnection of the electrical supply. Always ensure by using a suitable multimeter that no voltage is
present on any drive power terminals prior to commencing any work.
Where supply to the drive is through a plug and socket connector, do not disconnect until 10 minutes have elapsed after turning off the supply.
Ensure correct earthing connections. The earth cable must be sufficient to carry the maximum supply fault current which normally will be limited
by the fuses or MCB. Suitably rated fuses or MCB should be fitted in the mains supply to the drive, according to any local legislation or codes.
Ensure correct earthing connections and cable selection as per defined by local legislation or codes. The drive may have a leakage current of
greater than 3.5mA; furthermore the earth cable must be sufficient to carry the maximum supply fault current which normally will be limited by
the fuses or MCB. Suitably rated fuses or MCB should be fitted in the mains supply to the drive, according to any local legislation or codes.
Do not carry out any work on the drive control cables whilst power is applied to the drive or to the external control circuits.
Danger: Indicates a potentially hazardous situation other than
electrical, which if not avoided, could result in damage to property.