24
www.hysecurity.com
SLIDESMART CNX 15 BASIC MANUAL
MX4779 REV. A ©2019
OPERATOR CONFIGURATIONS
z
USAGE CLASS: UL 325 designations 1-4 (refer to
Safety Requirements page 6)
z
CLOSE TIMER: Number of seconds before open
gate initiates closure after all inputs are clear.
z
GATE HANDING: Direction gate opens when
viewed from the operator.
z
AC LOSS: Action operator performs during an
AC power loss. (Refer to Advanced manual)
z
BATTERY TYPE: Configure if using larger
capacity batteries. (Refer to Advanced Manual)
z
OPEN TIME ALERT: Activates relay (function 8)
when gate is open longer than selected time
period.
z
LOITERING ALERT: Activates relay (function 13)
when vehicle is over Outside Obstruction Loop
with gate closed longer than selected time
period.
z
LEARN LIMIT (SLIDE ONLY): Set to 1 to place
operator in learn limits mode. Installer must
then set open and close limits.
z
FACTORY DEFAULTS: Set to 1 to erase all
installer entered settings and return to factory
defaults.
z
OPERATOR TYPE: Factory set. Used only if
replacing the SmartCNX Controller.
z
MENU PIN: Allows installer to set a 4-digit
security pin to restrict access to CNX controller
menus.
SLIDE-only
OPERATOR
CONFIGURATIONS
USAGE CLASS
1 (RESIDENTIAL)
2 (PUBLIC)
3 (INDUSTRIAL)
4 (HIGH-SECURITY)
CLOSE TIMER
0 (OFF)
1 - 99 (SECONDS)
GATE HANDING
0 (NOT DEFINED)
1 (RIGHT)
2 (LEFT)
AC LOSS
0 (UPS FAIL OPEN)
1 (UPS FAIL CLOSE)
2 (AUTO OPEN)
3 (NO CLOSE TIMER)
BATTERY TYPE
0 (STANDARD)
1 (EXTENDED)
2 (MAXIMUM)
OPEN TIME ALERT
0 (0 SECS)
1 (15 SECS)
2 (45 SECS)
3 (75 SECS)
4 (105 SECS)
5 (135 SECS)
LOITERING ALERT
0 (0 SECS)
1 (15 SECS)
2 (45 SECS)
3 (75 SECS)
4 (105 SECS)
5 (135 SECS)
FACTORY DEFAULTS
0 (CUSTOM)
1 (RESET TO)
OPERATOR TYPE
1-17 (OPERATOR TYPE)
MENU PIN
0 0 0 0
LEARN LIMIT
0 (OFF)
1 (ON)
(0
†
)
(15
†
)
(0
†
)
†
†
†
†
†
†
†
†
†
= Indicates default