MX4779 REV. A ©2019
SLIDESMART CNX 15 BASIC MANUAL
www.hysecurity.com
23
INITIAL SETUP
CONFIGURE THE SETUP MENU (SLIDE)
The first time the SmartCNX controller powers on
set USAGE CLASS, GATE HANDING, and LEARN
LIMITS before normal operation.
1.
Set the AC and DC switches to ON the first time.
Software version appears on the display and
then USAGE CLASS - 0.
2. Press SELECT, press the UP or
DOWN
arrow to
navigate to the correct USAGE CLASS (page
6), and press SELECT to accept value.
3. Press the UP or
DOWN
arrow until GATE
HANDING appears on the display, press SELECT,
press the UP or
DOWN
arrow to navigate to
the correct option, and press SELECT to accept
value.
4.
STARTING UP flashes on the display, then
LEARN LIMITS appears.
5. Hold the
OPEN
button until the gate slides to
full open. Release the
OPEN
button.
Note: Press
CLOSE
to reverse direction.
Note: Do not set limits at the physical OPEN and
CLOSE stop. Leave a 1 to 2 inch (2.5 - 5 cm)
gap to allow slack in the chain to prevent wear
and avoid stress on gate hardware.
6. Press SELECT twice to store the full open
location in memory.
7. Hold the
CLOSE
button until the gate slides to
full close. Release the
CLOSE
button.
Note: Press OPEN to reverse direction.
8. Press SELECT twice to store the full close
location in memory.
9.
GATE CLOSED appears on the display. ALERT
15 flashes until the limit sensor detects the target
magnet on the next open cycle.
Note: NO AC POWER flashes if the AC power is not
connected or the AC power switch is set to
OFF
.
10.
Press OPEN and then CLOSE to cycle the
gate. An audible beep and both OPEN and
CLOSE limit LEDs flash when the target is first
recognized on the close cycle.
NAVIGATE THE MENUS
Press MENU/BACK to enter the menus or to exit
the current screen (up one level without saving any
changes).
Press the UP or DOWN arrow to change the current
selection until you find the one you want.
Press SELECT to access the menu or sub-menu.
Press SELECT to accept the current option or value.
Note: These navigation instructions are the same
throughout the SmartCNX controller menus.
HYSECURITY
B.1.00
1 , 2 , 3 , 4
USAGE CLASS
0 , 1 (RIGHT) , 2 (LEFT)
GATE HANDING
LEARN OPEN
INCHES: +000.0
LEARN CLOSE
INCHES: +000.0
HYSECURITY
GATE CLOSED
0 - No Handing set. Gate will not move until
handing is set.
1 - Viewing from operator side, gate opens to
the right
2 - Viewing from operator side, gate opens to
the left
Figure 27.
Configuring Setup Menu